1410 HUB Grid Undervoltage (en)
1. If accidental, due to temporary grid abnormalities; recovers automatically.
2. If frequent, check whether grid voltage is within acceptable range. If not, contact the local power operator. If acceptable, modify grid undervoltage protection threshold with operator consent.
3. If persists, check connection between AC switch and output power cable.
This article is based on official FoxESS technical documentation. For detailed manufacturer guides, please visit the FoxESS Support page.