FoxESS
FoxESS inverterek és akkumulátorok beállítási útmutatói, hibakódok és hibaelhárítási segédletek telepítők számára.
FoxESS hibakódok
- 1325-1333 DC Input MPPTn(n=4-12) Access Fault
- 1313-1324 Mpptn(n=1-12) High Voltage Fault
- 1505 External Communication Error (Battery 3)
- BS2 E80 (b7) Relay Fault.
- CQ-M ■ ● ● ● ● PCS Communication failed
- 1288 Communication Fault between Communication Board and HUB Board
- 1190 Temperature Sensor Alarm
- BS4 E10 (b4) Pre-charge fault.
- 1035 High Leakage Current Fault
- 1042 Grid Frequency High
- 1419 HUB Load Voltage Overfrequency
- 1193 EEPROM Write-read Alarm
- 1160 INV SelfCheck Permanent Fault
- 1261 Voltage Sensor Fault (Battery)
- 1259 Circuit Fault (Battery)
- BS1 E02 (b1) INT COM Internal communication fault.
- 1141 Redundant Detection Fault of Leak Current for Auxiliary DSP
- BS2 E40 (b6) Current Sensor Fault.
- 1479 Cell Overtemperature Protection (Battery 2)
- CQ-M ● / ● ● / Relay adhesion
- 1125 Ground Relay Fault
- 1483 Circuit Fault (Battery 2)
- 1250 Internal Communication Error (Battery)
- 1290 GEN Meter Communication Fault
- 1238 BDC2 Current Sampling Channel Fault
- 1192 Internal Fan Alarm
- 1191 External Fan Alarm
- 1040 Unbalanced Grid Voltage
- 1092 INV Relay Fault
- BS5 E40 (b6) Cell Temperature High Invalid.
- BS2 E01 (b0) CB Cell imbalance alarm.
- 1229 BDC Overtemperature Fault
- Temp Fault Inverter temperature is high.
- 1186 Off-grid Running Alarm
- 1045 Grid Line Voltage Over Limit
- 1257 BMS Cell Imbalance
- 1474 Internal Communication Error (Battery 2)
- CQ-M ■ / / ● / Over voltage fault
- 1051 Grid Phase Drop Fault
- 1487 Current Sensor Fault (Battery 2)
- 1345-1368 Stringn(n=1-24) Access Fault
- 1506 Internal Communication Error (Battery 3)
- Eps Over Load Over load in off-grid mode.
- 1106 Inverter Soft Start Timeout Fault
- BS5 E80 (b7) Balance Temperature High.
- 1430 Inconsistent Number of 485 and CAN Communications
- 1149 INV High Voltage Fault Under Off-grid
- 1177 Static Leak Current Permanent Fault
- 1508 Undervoltage Protection (Battery 3)
- BS3 E20 (b5) BMS_MR_Unmatch Unanswered charging request.
- BS5 E10 (b4) SUV Single cell '0V' fault.
- 1086 DC Input MPPT2 Access Fault
- BS1 E80 (b7) UT Under temperature fault.
- 1181 Arc Permanent Fault
- 1093 EPS Relay Fault
- CQ-M ■ / ● / ● Discharge over current
- 1129 INV Open-loop Self-checking fault
- 1478 Discharging Overcurrent Protection (Battery 2)
- 1103 Inverter Current Offset Fault
- 1189 DC Lightening Protector Anomaly
- 1511 Cell Overtemperature Protection (Battery 3)
- BS5 E01 (b0) Actor_Fault Relay drive circuit failure.
- 1513 BMS Cell Imbalance (Battery 3)
- 1420 HUB Load Voltage Underfrequency
- 1413 HUB Generator Overvoltage
- 1123 Grid Relay Fault
- Over Load Fault Over load in on-grid mode.
- 1241 BDC Soft Start Fault
- 1138 Redundant Detection Fault of Grid Voltage for Auxiliary DSP
- 1254 Discharging Overcurrent Protection (Battery)
- 1514 Hardware Protection (Battery 3)
- 1132 INV Frequency Fault Under Off-grid
- MDSP SPI Fault Communication between master and slave failed.
- 1223 BDC Hardware Overcurrent Fault
- 1303 Dehumidifier Communication Fault
- CQ-M ■ ● / ● / Short circuit Protection
- 1306 Water Ingress Fault
- Main Relay Open Grid relay keeps open.
- 1425 HUB Load Voltage Anomaly Fault
- 1088 DC Input MPPT3 Access Fault
- BS6 E08 (b3) AFE Fault (AFE UT/OT/UV/OV).
- CQ-M ● ● ● ● ● Other fault
- 1486 Temperature Sensor Fault (Battery 2)
- CQ-S Red LED on (1s on/1s off) Generic Alarm (CQ-S)
- 1412 HUB Grid Voltage Underfrequency
- 1030 AC Overcurrent
- BatCon Dir Fault Battery connection is reversed.
- 1305 Combustible Gas Fault
- Res Cur HW Fault Residual current detection device failed.
- 1284 Communication Fault between Communication Board and Built-in Meter
- M1 Close Fault Grid relay M1 keep close.
- 1157 Relay Permanent Fault
- 1308 Temperature Detector Fault
- 1108 Abnormal Frequency Detection Value
- 1447-1449 Reversed Batteryn(n=1-3) Polarity Connection Fault
- CQ-M ■ ● / ● ● AFE communication failed
- 1296 Communication Fault between Communication Board and BMS (duplicate)
- BS6 E40 (b6) Module addressing fault.
- 1044 Grid Phase Voltage Over Limit
- 1136 Load Overpower Fault
- 1294 AFCI fault lock device
- 1255 Cell Overtemperature Protection
- 1258 Hardware Protection (Battery)
- Bat Relay Short Circuit Battery relay keeps close.
- 1416 HUB Generator Voltage Underfrequency
- CQ-M ■ / / ● ● Over temperature fault
- 1476 Undervoltage Protection (Battery 2)
- Ground Fault Ground connection failed.
- 1293 Meter's Voltage line fault
- S2 Close Fault Grid relay S2 keep close.
- 1507 Overvoltage Protection (Battery 3)
- GridV Cons Fault Grid voltage sample value between master and slave is not consistent.
- CQ-M ● / ● / ● Temperature sampling failed
- 1282 Communication Fault between Communication Board and Auxiliary DSP
- BS3 E01 (b0) BMS_Typc_Unmatch Inconsistent cell capacity fault.
- 1520 Relay Fault (Battery 3)
- 1195 Grid Phase Change Alarm
- 1477 Charging Overcurrent Protection (Battery 2)
- 1310 Surge Protection Device Fault
- CQ-M ● ● ● / ● AFE failed (UV/OV/UT/OT)
- 1515 Circuit Fault (Battery 3)
- 1179 High BUS Voltage Imbalance Permanent Fault
- 1070 Bus Differential High Fault
- 1409 HUB Grid Overvoltage
- 1424 HUB Generator Relay Open Circuit Fault
- 1281 Communication Fault between Communication Board and Main DSP
- 1510 Discharging Overcurrent Protection (Battery 3)
- 1137 INV Low Voltage Fault Under Off-grid
- CQ-M ● / ● / / Internal total voltage sampling failed
- GridF Cons Fault Grid frequency sample value between master and slave is not consistent.
- 1421 HUB Grid Relay Short Circuit Fault
- 1517 Voltage Sensor Fault (Battery 3)
- CQ-M ● ● ● ● / Shutdown failed
- 1264 Relay Fault (Battery)
- 1252 Undervoltage Protection (Battery)
- 1417 HUB Load Overvoltage
- M2 Close Fault Grid relay M2 keep close.
- RDSP SPI Fault Communication between master and slave failed.
- BS5 E02 (b1) SOH_LOW State of Health low.
- 1263 Current Sensor Fault (Battery)
- BS6 E01 (b0) PreChg_Restemp High Precharge resistor overtemperature.
- 1057 Bus Transient Overvoltage
- 1488 Relay Fault (Battery 2)
- 1509 Charging Overcurrent Protection (Battery 3)
- BS2 E08 (b3) BMS Other Fault.
- 1188 AC Lightening Protector Anomaly
- Bat Volt Fault Battery voltage fault.
- 1473 External Communication Error (Battery 2)
- CQ-M ■ ● / / ● Pre-Charge failed
- 1115 Balancing Bridge Current Sampling Channel Fault
- 1422 HUB Grid Relay Open Circuit Fault
- 1481 BMS Cell Imbalance (Battery 2)
- 1249 External Communication Error (Battery)
- Iso Fault Isolation failed.
- CQ-M ■ / ● / / Under temperature fault
- 1428 Inconsistent Settings of Paralleled Inverters in HUB Mode
- Res Cur Fault Residual current is high.
- 1287 RTC Read-Write Fault
- ARM EEPROM Fault Manager EEPROM is fault.
- BS5 E20 (b5) Extreme overvoltage fault (CellVolt R&H Invalid).
- 1482 Hardware Protection (Battery 2)
- CQ-M ● / / / ● HVB FUSE fault
- Inv EEPROM Fault Inverter EEPROM is fault.
- 1411 HUB Grid Voltage Overfrequency
- 1185 Abnormal Grid Startup Voltage
- CQ-M ■ ● ● / ● IVU Communication failed
- CQ-M ● ● / / / Relay drive failed
- 1084 Balancing Bridge Hardware Overcurrent
- 1095 ESTOP Trigger
- 1518 Temperature Sensor Fault (Battery 3)
- BS1 E04 (b2) OV Over voltage fault.
- S1 Close Fault Grid relay S1 keep close.
- 1444-1446 BDCn(n=1-3) Pre-charging Resistor Fault
- CQ-M ● / ● ● ● Relay Not Close
- CQ-M ● ● / ● ● Single voltage high permanently failed
- Eps Relay Fault EPS relay failed.
- BS1 E40 (b6) OT Over temperature fault.
- 1244 BDC Average Overvoltage Fault
- 1116 Ground Impedance Fault
- 1091 Off grid command conflict
- 1034 DC Component Current Fault
- 1176 BST Hardware Overcurrent Permanent Fault
- 1253 Charging Overcurrent Protection (Battery)
- 1410 HUB Grid Undervoltage
- 1295 Communication Fault between Communication Board and BMS (duplicate)
- MDSP Smpl Fault Master sample detection circuit failed.
- 1112 Internal Control Diagnosis Fault
- 1485 Voltage Sensor Fault (Battery 2)
- BS2 E10 (b4) Voltage Sensor Fault.
- 1109 Leak Current CT Self-checking Fault
- Pv Volt Fault PV voltage out of range.
- Dci Cons Fault DCI sample value between master and slave is not consistent.
- BS6 E02 (b1) short_current Hardware overcurrent fault.
- BS2 E02 (b1) Hardware Protect.
- 1071 Bus Hardware Overvoltage
- 1283 Communication Fault between Communication Board and BMS
- CQ-M ● / / ● ● Power failed
- 1173 Internal Control Diagnosis Permanent Fault
- 1048 High DC Component Voltage When Off-grid
- 1475 Overvoltage Protection (Battery 2)
- 1174 BUS Hardware Overvoltage Permanent Fault
- CQ-M ■ / ● ● ● Warm up film switch adhesion
- CQ-M ■ / ● ● / Charge over current
- 1178 BUS Overvoltage Permanent Fault
- 1427 HUB Overload Fault
- Bat Buck Fault Battery buck circuit mosfet failed.
- 1262 Temperature Sensor Fault (Battery)
- RDSP Smpl Fault Slave sample detection circuit failed.
- BS6 E10 (b4) IVU Communication fault.
- 1450-1452 Batteryn(n=1-3) Pre-charging Relay Fault
- 1194 Slave/Sub to Master/Main Communication Alarm
- 1426 HUB and Inverter Communication Fault
- 1429 HUB Overtemperature
- 1418 HUB Load Undervoltage
- 1304 Combustible Gas Detector Communication Fault
- 1145 Arc Fault
- Rc Cons Fault Residual current sample value between master and slave is not consistent.
- PvCon Dir Fault PV connection is reversed.
- 1046 Unbalanced Inverter Current
- 1480 Cell Undertemperature Protection (Battery 2)
- Meter Lost Fault Communication between meter and inverter interrupted.
- 1512 Cell Undertemperature Protection (Battery 3)
- 1251 Overvoltage Protection (Battery)
- 1237 BDC1 Current Sampling Channel Fault
- 1139 Redundant Detection Fault of Grid Frequency for Auxiliary DSP
- 1102 Inverter Current DC Component Offset Fault
- 1423 HUB Generator Relay Short Circuit Fault
- CQ-M ● ● ● / / SOH low protection
- BS1 E01 (b0) EXT COM Communication fault with PCS (External Communication).
- CQ-M ■ ● ● / / Module Addressing failed
- 1256 Cell Undertemperature Protection
- 1309 SN Fault
- 1154 INV Overcurrent Permanent Fault
- 1224 BDC3 Current Sampling Channel Fault
- 1456-1458 BDCn(n=1-3) Self-checking Fault
- 1043 Grid Frequency Low
- 1163 Balancing Bridge Overcurrent Permanent Fault
- 1085 DC Input MPPT1 Access Fault
- BS2 E20 (b5) Temperature Sensor Fault.
- 1285 Communication Fault between Communication Board and Grid Meter
- BS1 E08 (b3) UV Under voltage fault.
- 1036 Static Leakage Current Fault
- 1289 Solar Meter Communication Fault
- BS1 E20 (b5) OCD Discharge over current.
- 1414 HUB Generator Undervoltage
- 1124 Low Insulation Impedance Fault
- 1291 Communication Fault between the Master and slave
- 1182 BDC Overcurrent Permanent Fault
- CQ-M ■ ● ● ● / BMU Communication failed
- 1099 Overtemperature Protection
- 1050 Inverter Hardware Overcurrent
- 1441-1443 BDCn(n=1-3) Average Low Voltage Fault (Total battery voltage is below undervoltage value in non-charging mode)
- 1292 Meter's CT line fault
- BS6 E04 (b2) AFE Communication Fault.
- 1415 HUB Generator Voltage Overfrequency
- CQ-M ■ / / / ● Under voltage fault
- CQ-M ● ● / / ● Single Cell '0V' fault
- 1107 BUS Soft Start Fault
- CQ-M ● / / ● / Module FUSE fault
- Bat Relay Open Battery relay keeps open.
- SCI Fault Communication between master and manager failed.
- 1243 BDC transient Overvoltage Fault
- 1459-1461 Batteryn(n=1-3) Input Fault
- CQ-M ● ● / ● / Temperature high permanent failed
- 1220 BDC Over Current Fault
- BS1 E10 (b4) OCC Charge over current.
- 1286 Communication Board Flash Writing Fault
- 1307 Smoke Detector Fault
- 1519 Current Sensor Fault (Battery 3)